In vivo detection of choline in ovarian tumors using 3D magnetic resonance spectroscopy
This study evaluated the clinical feasibility of 3D magnetic resonance spectroscopy for detecting choline peaks in ovarian masses, finding 89% sensitivity for malignancy and 84% specificity.
One-sentence paraphrase of the abstract; not a substitute for reading it. No clinical advice. How this works
This study assessed the clinical feasibility of using 3D proton magnetic resonance spectroscopy to detect choline peaks in ovarian masses at 1.5 Tesla. Researchers prospectively evaluated 23 ovarian masses in 16 patients, comparing spectral findings against histopathological results from surgery. The technique demonstrated an 89% sensitivity for malignancy and an 84% specificity, with choline peaks present in most malignant tumors but absent in healthy pelvic tissues. However, three benign tumors also showed choline peaks, limiting the method's specificity for distinguishing cancer from non-cancerous conditions. Relevance to endometriosis: one of the four benign lesions included in the study was identified as endometriosis, which did not exhibit a choline peak.
Read from the paper's body, not the abstract. Not a substitute for reading the paper. No clinical advice. How this works
Abstract
Full text
2,289 characters
· extracted from
oa-doi-fallback
· 4 sections
· click to expand
Objectives
Materials and methods
Results
Conclusions
Text is read by the "Ask this paper" AI Q&A widget below. Extraction quality varies by source — PMC NXML preserves structure cleanly, OA-HTML may include some navigation residue, and OA-PDF can have broken hyphenation. The publisher copy (via DOI) is the canonical version.
My notes (saved in your browser only)
Answers must be backed by verbatim quotes from this paper's full text. Hallucinated quotes are dropped automatically; if no verbatim passage answers the question, we say so. How this works
Condition tags
MeSH descriptors
Citation neighborhood (no data yet)
We don't have any in-corpus citations linked to this paper yet. The paper's references may be in our DB but unresolved to ``paper_id`` (resolution happens at ingest when the cited DOI matches a row we already have). Run the cross-source citation reconcile pass to retry.
Source provenance
- europepmc
- last seen: 2026-10-18T09:30:06.152893+00:00
- pubmed
- last seen: 2026-10-08T21:08:47.456808+00:00
- unpaywall
- last seen: 2026-10-18T06:28:46.490043+00:00
Courtesy of the U.S. National Library of Medicine