{"paper_id":"fad6c0be-c613-466b-9656-2dfb5da79309","body_text":"Abstract\nObjective:\nTo develop and internally validate a nomogram based on preprocedural magnetic resonance imaging (MRI) and clinical features to predict high ablation difficulty in patients with adenomyosis (AM) undergoing ultrasound-guided high-intensity focused ultrasound (US-guided HIFU).\nMethods:\nThis retrospective study included 486 patients with AM who underwent US-guided HIFU ablation. Patients were randomly divided in a 7:3 ratio into a training cohort (n = 340) and an internal validation cohort (n = 146). An ablation difficulty score ranging from 0 to 6 was established based on the energy efficiency factor (EEF), treatment intensity, and nonperfused volume ratio (NPVR). Patients were classified into a low-ablation-difficulty group (0–3 points) and a high-ablation-difficulty group (4–6 points). In the training cohort, candidate predictors were initially screened using univariable analysis and least absolute shrinkage and selection operator (LASSO) logistic regression. Multivariable logistic regression was subsequently performed to identify the final predictors and construct the nomogram. Model performance was evaluated in both cohorts using the area under the receiver operating characteristic curve (AUC), calibration curves, and decision curve analysis (DCA).\nResults:\nAge, uterine volume, abdominal wall thickness, Kishi classification, T2-weighted imaging (T2WI) signal intensity, and the degree of contrast enhancement on T1-weighted imaging (T1WI) were identified as independent predictors of high ablation difficulty. The nomogram demonstrated good discrimination, with AUCs of 0.903 and 0.923 in the training and internal validation cohorts, respectively. Calibration curves showed good agreement between the predicted and observed probabilities. DCA indicated that the nomogram provided clinical net benefit across threshold probability ranges of approximately 5%–80% in the training cohort and 5%–75% in the internal validation cohort.\nConclusion:\nThe nomogram based on preprocedural MRI and clinical features demonstrated good predictive performance for US-guided HIFU ablation difficulty in patients with AM and may support patient selection, preprocedural risk assessment, and individualized treatment planning.\n1 Introduction\nAdenomyosis (AM) is a common benign gynecologic disorder affecting women of reproductive age. Histopathologically, it is characterized by the presence of ectopic endometrial glands and stroma within the myometrium, accompanied by surrounding smooth muscle hyperplasia, fibrosis, and focal or diffuse myometrial thickening (\n, ). Imaging-based studies have reported a prevalence of approximately 20%–35% among women of reproductive age ( – ). Symptomatic AM commonly presents with heavy menstrual bleeding, dysmenorrhea, chronic pelvic pain, and infertility, all of which can substantially impair patients’ quality of life ( ). Current treatment options for AM include medical therapy, surgery, uterine artery embolization, and image-guided ablation ( , ). However, hysterectomy results in permanent loss of fertility; symptoms may recur after discontinuation of medical therapy; and conservative surgery and uterine artery embolization remain limited by procedural morbidity, recurrence, the need for reintervention, and potential adverse effects on fertility ( – ). Therefore, minimally invasive or noninvasive treatments that provide symptom relief while preserving the uterus and reproductive potential are of considerable clinical value in the management of AM.Ultrasound-guided high-intensity focused ultrasound (US-guided HIFU) is a noninvasive thermal ablation technique that concentrates acoustic energy within the target lesion under real-time ultrasound guidance, thereby inducing irreversible coagulative necrosis of the target tissue (14, 15). HIFU has been used for solid tumor ablation, focal treatment of prostate cancer, and selected neurological disorders, and has increasingly been adopted as a uterus-preserving treatment for AM (16–21). However, because AM lesions exhibit considerable heterogeneity in terms of volume, anatomical location, perfusion characteristics, and baseline magnetic resonance imaging (MRI) signal profiles, substantial interpatient variations remain regarding ablation efficiency and procedural complexity (22, 23).\nFrom a clinical perspective, preprocedural identification of patients at high risk of difficult ablation may improve patient selection and periprocedural management and provide an objective basis for patient counseling. Previous studies have shown that preprocedural clinical parameters, MRI phenotypes, and radiomic features are associated with HIFU treatment outcomes in patients with AM (24–26). More recently, MRI radiomics, deep learning, and combined clinical and imaging features have been investigated for predicting the nonperfused volume ratio (NPVR), ablation rate, or energy efficiency after HIFU treatment. However, studies specifically addressing the overall ablation difficulty associated with US-guided HIFU remain limited, and a well-validated tool for quantitative preprocedural risk stratification is not yet available (27–29). Accordingly, an assessment framework incorporating ablation efficiency, energy expenditure, and procedural complexity is needed to support the development of a preprocedural prediction model.\n2 Materials and methods\n2.1 Study population\nThis single-center retrospective study was approved by the Ethics Committee of the Affiliated Hospital of North Sichuan Medical College (approval no. 2024ER713-1). The requirement for informed consent was specifically waived by the Ethics Committee because this retrospective study used de-identified clinical, imaging, and treatment-related data, involved no additional intervention or patient contact, and posed no more than minimal risk to participants. Consecutive patients diagnosed with AM who underwent US-guided HIFU ablation at our institution between March 2016 and March 2024 were screened for eligibility. The inclusion criteria were as follows: (1) age 18–60 years; (2) presence of AM-related symptoms, including heavy menstrual bleeding or dysmenorrhea; (3) underwent US-guided HIFU ablation; (4) completion of both unenhanced and contrast-enhanced pelvic MRI within 1 week before ablation and within 24 h after ablation. The exclusion criteria were as follows: (1) concomitant uterine leiomyomas; (2) a history of myomectomy and/or surgical excision of adenomyotic lesions; (3) treatment with a gonadotropin-releasing hormone agonist (GnRH-a) and/or estrogen–progestin therapy within 3 months before ablation; (4) menstruation at the time of treatment, pregnancy, or lactation; (5) acute or chronic pelvic inflammatory disease; (6) malignancy or severe cardiopulmonary disease; and (7) incomplete clinical, imaging, or treatment-related data.\nDuring the study period, a total of 1,032 patients were screened for eligibility. Of these, 546 patients were excluded based on the predefined criteria: 366 with concomitant uterine leiomyomas, 3 with a history of myomectomy and/or surgical excision of AM lesions, 43 who received GnRH-a and/or estrogen–progestin therapy within 3 months prior to ablation, and 134 with incomplete data, including 102 (76.1%) with missing MRI data and 32 (23.9%) with incomplete clinical records. Complete-case analysis was therefore performed. 486 patients were included in the final analysis (Figure 1).\nFigure 1\n2.2 Clinical data\nPreprocedural clinical data collected for all patients with AM included demographic characteristics [age, height, weight, and body mass index (BMI)], obstetric history (parity, number of induced abortions, and number of cesarean deliveries), the presence of a lower abdominal wall scar, and baseline hemoglobin level.\n2.3 Pelvic mri protocol and image analysis\nAll patients underwent unenhanced and contrast-enhanced pelvic MRI within 1 week before US-guided HIFU ablation using a 3.0-T MRI system (Siemens Healthcare, Erlangen, Germany). The imaging protocol included conventional T1-weighted imaging [T1WI; repetition time [TR]/echo time [TE], 500/13 ms; slice thickness, 4 mm], T2-weighted imaging (T2WI; TR/TE, 2300/100 ms; slice thickness, 4 mm), and contrast-enhanced T1WI (TR/TE, 6.23/2.91 ms; slice thickness, 4 mm). Contrast-enhanced imaging was initiated 10 s after intravenous bolus administration of gadodiamide through an antecubital vein. Images were acquired in the axial, sagittal, and coronal planes. All pelvic MR images were independently reviewed by two radiologists, each with 10 years of experience in abdominal imaging, who were blinded to the patients’ ablation-difficulty classification and treatment outcomes. Disagreements were resolved by consensus. Inter-reader agreement was additionally assessed in a randomly selected 30% subsample of the study population, using Cohen's kappa for categorical imaging features and intraclass correlation coefficients for continuous imaging measurements. The evaluated imaging features included abdominal wall thickness, presence of a concomitant ovarian cyst, uterine volume and position, Kishi classification of the adenomyotic lesion (30), lesion volume, location, and symmetry, distance from the lesion center to the anterior abdominal skin surface, distance from the lesion center to the sacrum, and the minimum distance from the posterior lesion margin to the sacrum. MRI signal characteristics included lesion signal intensity and homogeneity on T2WI, the number of intralesional T2WI hyperintense foci, lesion signal intensity and homogeneity on T1WI, and the degree and homogeneity of contrast enhancement on T1WI.\nUterine and lesion volumes were calculated using the ellipsoid formula based on three orthogonal diameters. T1WI and T2WI signal intensity was categorized as hypo-, iso-, or hyperintense relative to the adjacent normal myometrium. Lesions with a uniform distribution of internal signal intensity or contrast enhancement were classified as homogeneous; otherwise, they were classified as heterogeneous. The number of T2WI hyperintense foci was determined by reviewing the slice showing the largest cross-sectional area of the lesion together with the adjacent slices. Contrast enhancement on T1WI was categorized as mild, moderate, or marked according to the magnitude of post-contrast signal increase and its signal intensity relative to the adjacent normal myometrium.\n2.4 US-guided hifu ablation protocol and procedural parameters\nAll US-guided HIFU procedures were performed using a JC200 focused ultrasound tumor therapeutic system (Chongqing Haifu Medical Technology Co., Ltd., Chongqing, China). All procedures were performed by two experienced HIFU physicians, each with approximately 10 years of HIFU experience. Patients were placed in the prone position, with the therapeutic transducer positioned against the lower abdomen. The urinary bladder was moderately filled through a urinary catheter to optimize the acoustic window. Sedation and analgesia were administered, and respiratory rate, heart rate, oxygen saturation, and blood pressure were monitored throughout the procedure.\nThe system operated at a frequency of 0.98 MHz, with an acoustic power range of 50–400 W. Target localization, treatment planning, and ablation monitoring were performed under real-time ultrasound guidance. The adenomyotic lesions were ablated layer by layer using a point–plane–volume sonication strategy. Treatment was terminated when satisfactory grayscale changes were observed within the planned target area on real-time ultrasound or when the predefined ablation extent had been achieved according to treatment planning and safety considerations. Immediately after ablation, contrast-enhanced ultrasound (CEUS) was performed following intravenous administration of sulfur hexafluoride microbubbles (SonoVue; Bracco, Milan, Italy) to assess the immediate ablation extent. The system automatically recorded the mean sonication power, total treatment time, sonication time, and total energy delivered.\n2.5 Ablation-related metrics\nNonperfused volume (NPV), NPVR, EEF, and treatment intensity were used to calculate the US-guided HIFU ablation difficulty score. NPV was measured on contrast-enhanced pelvic MRI performed within 24 h after ablation. Post-ablation MRI was performed using the same MRI system and contrast-enhanced imaging protocol as the preprocedural examination. The longitudinal, transverse, and anteroposterior diameters of the nonperfused region were measured, and NPV was calculated using the ellipsoid formula rather than voxel-wise segmentation. NPVR represents the proportion of the adenomyotic lesion rendered nonperfused after treatment and was calculated as follows (31):A higher NPVR indicates that a greater proportion of the adenomyotic lesion was ablated.\nAdenomyotic lesion volume and NPV were calculated from three orthogonal diameters—the longitudinal (D1), transverse (D2), and anteroposterior (D3) diameters—using the ellipsoid formula (32):Energy efficiency factor (EEF), expressed in J/mm3, represents the acoustic energy required to ablate a unit volume of lesion tissue and was calculated as follows (25):Where is the focusing coefficient, set at 0.7; P is the acoustic power (W); is the sonication time (s); and is the NPV (mm3).\nTreatment intensity, expressed in s/h, represents the effective sonication time per hour of treatment and was calculated as follows (33):\n2.6 Development of the composite ablation difficulty score\nBased on a previously proposed scoring framework for US-guided HIFU ablation difficulty (34), we developed an exploratory composite ablation difficulty score tailored to the treatment characteristics of AM. The EEF, treatment intensity, and NPVR were each categorized into three levels according to their relationships with ablation difficulty and assigned 0, 1, or 2 points. NPVR, EEF, and treatment intensity were selected to reflect ablation extent, energy efficiency, and sonication burden, respectively. Equal weighting was adopted for simplicity and interpretability, as no validated weighting scheme is currently available. The Q2 and Q3 cutoff values for EEF and treatment intensity were derived from their distributions in the training cohort and applied unchanged to the internal validation cohort. In the absence of validated clinical cutoffs, Q2 and Q3 were selected as pragmatic thresholds to represent progressively higher ablation difficulty. These thresholds were regarded as cohort-specific operational cutoffs rather than established clinical cutoffs. The three component scores were summed to generate a total score ranging from 0 to 6, with higher scores indicating greater ablation difficulty. Patients were classified into the low-difficulty group (≤3 points) or the high-difficulty group (>3 points). A total score >3, corresponding to the upper half of the 0–6 scale, was defined as high ablation difficulty and regarded as an exploratory operational cutoff. The detailed scoring criteria are presented in Table 1.\nTable 1\n| Variable | Category | Score |\n|---|---|---|\n| EEF | <Q2 | 0 |\n| Q2 ≤ EEF < Q3 | 1 | |\n| ≥Q3 | 2 | |\n| Treatment intensity (s/h) | <Q2 | 0 |\n| Q2 ≤ Treatment intensity < Q3 | 1 | |\n| ≥Q3 | 2 | |\n| NPVR | <50% | 2 |\n| 50% ≤ NPVR < 70% | 1 | |\n| ≥70% | 0 |\nCriteria for the ablation difficulty score.\nQ2 denotes the median, and Q3 denotes the upper quartile. EEF, energy efficiency factor; NPVR, nonperfused volume ratio. A total score of 0–3 was defined as low ablation difficulty, whereas a score of 4–6 was defined as high ablation difficulty.\n2.7 Statistical analysis\nStatistical analyses were performed using R software (version 4.5.2). The study population was randomly divided into a training cohort and an internal validation cohort at a ratio of 7:3. The training cohort was used for variable selection and model development, whereas the internal validation cohort was used for model validation. The age cutoff of 35 years was selected because it is widely used in obstetric and reproductive medicine as a conventional marker of reproductive aging and declining fertility, rather than as a validated threshold for HIFU ablation difficulty. Continuous variables were assessed for normality. Normally distributed variables were expressed as the mean ± standard deviation and compared using Welch's t test. Non-normally distributed variables were reported as the median and interquartile range [M (Q1, Q3)] and compared using the Wilcoxon rank-sum test. Categorical variables were presented as frequencies and percentages [n (%)] and compared using Pearson's χ2 test or Fisher's exact test, as appropriate. Complete-case analysis was performed because patients with incomplete essential clinical or MRI data were excluded. Standardized mean differences (SMDs) were additionally calculated to assess the balance of baseline characteristics between the training and internal validation cohorts. An absolute SMD <0.10 was considered to indicate negligible imbalance.\nWithin the training cohort, candidate variables were initially screened using univariable analysis. Variables with P < 0.10 were subsequently entered into least absolute shrinkage and selection operator (LASSO) logistic regression for further variable selection. Variables retained by LASSO were then included in a multivariable logistic regression analysis to identify the final independent predictors and construct the nomogram. Potential multicollinearity among candidate predictors was assessed using correlation analysis and variance inflation factors (VIFs). Regression results were reported as odds ratios (ORs), 95% confidence intervals (CIs), and corresponding P values. Model discrimination, calibration, and clinical utility were evaluated in both the training and internal validation cohorts using the area under the receiver operating characteristic curve (AUC), calibration curves, and decision curve analysis (DCA), respectively. Calibration curves and optimism-corrected internal validation of the final six-predictor model were performed using 1,000 bootstrap resamples. Calibration intercept, calibration slope, Brier score, sensitivity, specificity, PPV, and NPV were additionally evaluated. All statistical tests were two-sided, and P < 0.05 was considered statistically significant. Sensitivity analyses were performed to assess whether the main findings were dependent on the original threshold-based outcome definition. EEF and treatment intensity were analyzed as continuous outcomes, and NPVR <70% was used as an alternative clinically interpretable binary endpoint. Spearman correlation analysis was performed among NPV, NPVR, EEF, treatment intensity, and the total difficulty score to assess potential dependence among the components of the composite endpoint.\n3 Results\n3.1 Baseline characteristics\nA total of 486 patients were included and randomly divided into a training cohort (n = 340) and an internal validation cohort (n = 146) at an approximate 7:3 ratio (Table 2). No statistically significant differences were observed between the training and internal validation cohorts in baseline clinical or MRI characteristics (all P > 0.05). SMDs were generally small across most baseline variables, with some variation observed for selected imaging characteristics (Table 2).\nTable 2\n| Characteristic | Cohort | P value | ||\n|---|---|---|---|---|\n| Training Cohort n = 340 | Internal Validation Cohort n = 146 | SMD | ||\n| Age (years), n (%) | 0.564a | 0.058 | ||\n| ≥35 | 284 (83.5%) | 125 (85.6%) | ||\n| ˂35 | 56 (16.5%) | 21 (14.4%) | ||\n| BMI (kg/m2), n (%) | 0.989a | 0.001 | ||\n| ˂25 | 268 (78.8%) | 115 (78.8%) | ||\n| ≥25 | 72 (21.2%) | 31 (21.2%) | ||\n| Hb (g/L), n (%) | 0.886a | 0.014 | ||\n| ˂110 | 142 (41.8%) | 62 (42.5%) | ||\n| ≥110 | 198 (58.2%) | 84 (57.5%) | ||\n| Uterine volume (cm3), Median (Q1, Q3) | 231 (161, 313) | 218 (165, 332) | 0.823b | 0.052 |\n| Adenomyotic lesion volume (cm3), Median (Q1, Q3) | 48 (23, 88) | 46 (26, 103) | 0.483b | 0.129 |\n| Abdominal wall thickness (mm), Median (Q1, Q3) | 25 (20, 31) | 25 (20, 29) | 0.390b | 0.110 |\n| Distance from lesion center to abdominal wall (mm), Median (Q1, Q3) | 82 (64, 102) | 83 (66, 105) | 0.308b | 0.099 |\n| Distance from lesion center to sacrum (mm), Median (Q1, Q3) | 37 (30, 46) | 35 (29, 44) | 0.386b | 0.081 |\n| Shortest distance from the lesion to the sacrum (mm), Median (Q1, Q3) | 10 (5, 20) | 10 (6, 16) | 0.371b | 0.103 |\n| Parity, Median (Q1, Q3) | 1.00 (1.00, 2.00) | 2.00 (1.00, 2.00) | 0.334b | 0.087 |\n| Number of abortions, Median (Q1, Q3) | 2.00 (1.00, 3.00) | 2.00 (1.00, 3.00) | 0.350b | 0.064 |\n| Number of cesarean deliveries, Median (Q1, Q3) | 0.00 (0.00, 0.50) | 0.00 (0.00, 1.00) | 0.645b | 0.015 |\n| Concomitant ovarian cyst, n (%) | 0.195a | 0.125 | ||\n| No | 307 (90.3%) | 126 (86.3%) | ||\n| Yes | 33 (9.7%) | 20 (13.7%) | ||\n| Uterine position, n (%) | 0.805c | 0.070 | ||\n| Ante-position | 229 (67.4%) | 95 (65.1%) | ||\n| Mid-position | 9 (2.6%) | 3 (2.1%) | ||\n| Retro-position | 102 (30.0%) | 48 (32.9%) | ||\n| Adenomyosis lesion location, n (%) | 0.128a | 0.288 | ||\n| Anterior wall | 66 (19.4%) | 32 (21.9%) | ||\n| Posterior wall | 147 (43.2%) | 64 (43.8%) | ||\n| Anterior and posterior walls | 71 (20.9%) | 31 (21.2%) | ||\n| Lateral walls | 31 (9.1%) | 4 (2.7%) | ||\n| Fundus | 25 (7.4%) | 15 (10.3%) | ||\n| Lesion symmetry, n (%) | 0.602a | 0.051 | ||\n| No | 250 (73.5%) | 104 (71.2%) | ||\n| Yes | 90 (26.5%) | 42 (28.8%) | ||\n| Lower abdominal scar, n (%) | 0.659a | 0.044 | ||\n| No | 233 (68.5%) | 103 (70.5%) | ||\n| Yes | 107 (31.5%) | 43 (29.5%) | ||\n| Kishi classification, n (%) | 0.304a | 0.188 | ||\n| I | 151 (44.4%) | 60 (41.1%) | ||\n| II | 59 (17.4%) | 22 (15.1%) | ||\n| III | 37 (10.9%) | 12 (8.2%) | ||\n| IV | 93 (27.4%) | 52 (35.6%) | ||\n| T2WI signal intensity, n (%) | 0.714a | 0.036 | ||\n| Hypointense/Isointense | 204 (60.0%) | 85 (58.2%) | ||\n| Hyperintense | 136 (40.0%) | 61 (41.8%) | ||\n| Number of T2WI hyperintense foci, n (%) | 0.462a | 0.073 | ||\n| ≤5 | 152 (44.7%) | 60 (41.1%) | ||\n| >5 | 188 (55.3%) | 86 (58.9%) | ||\n| T2WI signal homogeneity, n (%) | 0.939a | 0.008 | ||\n| Homogeneous | 92 (27.1%) | 40 (27.4%) | ||\n| Heterogeneous | 248 (72.9%) | 106 (72.6%) | ||\n| T1WI signal intensity, n (%) | 0.723a | 0.035 | ||\n| Hypointense/Isointense | 313 (92.1%) | 133 (91.1%) | ||\n| Hyperintense | 27 (7.9%) | 13 (8.9%) | ||\n| T1WI signal homogeneity, n (%) | 0.676a | 0.042 | ||\n| Homogeneous | 90 (26.5%) | 36 (24.7%) | ||\n| Heterogeneous | 250 (73.5%) | 110 (75.3%) | ||\n| T1WI contrast enhancement, n (%) | 0.655a | 0.044 | ||\n| Mild/Moderate | 214 (62.9%) | 95 (65.1%) | ||\n| Marked | 126 (37.1%) | 51 (34.9%) | ||\n| T1WI enhancement homogeneity, n (%) | 0.496a | 0.068 | ||\n| Homogeneous | 106 (31.2%) | 41 (28.1%) | ||\n| Heterogeneous | 234 (68.8%) | 105 (71.9%) |\nComparison of preprocedural clinical and MRI characteristics between the training and internal validation cohorts.\nContinuous variables are presented as the median (interquartile range), and categorical variables as n (%). SMD, standardized mean difference; BMI, body mass index; Hb, hemoglobin; T1WI, T1-weighted imaging; T2WI, T2-weighted imaging.\nPearson's Chi-squared test.\nWilcoxon rank sum test.\nFisher's exact test.\n3.2 Treatment parameters and outcome characteristics\nTreatment parameters and the distribution of ablation difficulty in the training and internal validation cohorts are summarized in Table 3. In the training cohort, 256 patients were classified into the low-difficulty group and 84 into the high-difficulty group. In the internal validation cohort, 116 and 30 patients were classified into the low- and high-difficulty groups, respectively. No statistically significant differences were observed between the two cohorts in treatment parameters or the distribution of ablation difficulty (all P > 0.05). Spearman analysis showed a strong negative correlation between NPV and EEF (ρ = −0.866, P < 0.001) and a moderate negative correlation between NPVR and EEF (ρ = −0.456, P < 0.001) (Supplementary Table S7). Inter-reader agreement was high for Kishi classification (κ = 0.893), T2WI signal intensity (κ = 0.902), T1WI contrast enhancement (κ = 0.926), uterine volume (ICC = 0.997), and abdominal wall thickness (ICC = 0.975) in the randomly selected 30% subsample; complete results are provided in Supplementary Table S6.\nTable 3\n| Characteristic | Group | P value | |\n|---|---|---|---|\n| Training Cohort n = 340 | Internal Validation Cohort n = 146 | ||\n| Mean sonication power (W), Median (Q1, Q3) | 400 (400, 400) | 400 (400, 400) | 0.148a |\n| Treatment time (min), Median (Q1, Q3) | 60 (47, 80) | 61 (47, 80) | 0.602a |\n| Sonication time (s), Median (Q1, Q3) | 551 (390, 802) | 563 (392, 786) | 0.898a |\n| Treatment intensity (s/h), Mean ± SD | 572 ± 138 | 565 ± 123 | 0.598b |\n| EEF, Median (Q1, Q3) | 5 (3, 11) | 5 (2, 8) | 0.206a |\n| NPV (cm3), Median (Q1, Q3) | 32 (14, 59) | 32 (15, 65) | 0.345a |\n| NPVR (%), Median (Q1, Q3) | 71 (50, 86) | 69 (54, 89) | 0.366a |\n| Total score, Median (Q1, Q3) | 2.00 (1.00, 3.00) | 2.00 (1.00, 3.00) | 0.395a |\n| Ablation difficulty, n (%) | 0.321c | ||\n| High-difficulty group | 84 (24.7%) | 30 (20.5%) | |\n| Low-difficulty group | 256 (75.3%) | 116 (79.5%) |\nComparison of treatment parameters and the distribution of ablation difficulty between the training and internal validation cohorts.\nWilcoxon rank sum test.\nWelch's t test.\nPearson's Chi-squared test.\n3.3 Univariable analysis of candidate predictors\nIn the training cohort, univariable analysis showed that 13 of the 25 candidate variables were associated or potentially associated with high ablation difficulty (P < 0.10). These variables were age, uterine volume, adenomyotic lesion volume, abdominal wall thickness, distance from the lesion center to the anterior abdominal skin, number of cesarean deliveries, uterine position, Kishi classification, T2WI signal intensity, number of T2WI hyperintense foci, T2WI signal homogeneity, degree of contrast enhancement on T1WI, and T1WI enhancement homogeneity (Table 4).\nTable 4\n| Characteristic | Training Cohort (n = 340) | ||\n|---|---|---|---|\n| Low-difficulty group n = 256 | High-difficulty group n = 84 | P value | |\n| Age (years), n (%) | <0.001 | ||\n| ≥35 | 234 (91.4%) | 50 (59.5%) | |\n| <35 | 22 (8.6%) | 34 (40.5%) | |\n| BMI (kg/m2), n (%) | 0.195 | ||\n| ˂25 | 206 (80.5%) | 62 (73.8%) | |\n| ≥25 | 50 (19.5%) | 22 (26.2%) | |\n| Hb (g/L), n (%) | 0.298 | ||\n| ˂110 | 111 (43.4%) | 31 (36.9%) | |\n| ≥110 | 145 (56.6%) | 53 (63.1%) | |\n| Uterine volume (cm3), Median (Q1, Q3) | 241 (174, 319) | 193 (146, 296) | 0.004 |\n| Adenomyotic lesion volume (cm3), Median (Q1, Q3) | 52 (26, 94) | 33 (13, 75) | 0.004 |\n| Abdominal wall thickness (mm), Mean ± SD | 25 ± 8 | 29 ± 5 | <0.001 |\n| Distance from lesion center to abdominal wall (mm), Median (Q1, Q3) | 80 (64, 100) | 88 (66, 110) | 0.014 |\n| Distance from lesion center to sacrum (mm), Median (Q1, Q3) | 37 (30, 46) | 35 (28, 44) | 0.267 |\n| Shortest distance from the lesion to the sacrum (mm), Median (Q1, Q3) | 11 (5, 20) | 10 (6, 20) | 0.870 |\n| Parity, Median (Q1, Q3) | 1.00 (1.00, 2.00) | 1.00 (1.00, 2.00) | 0.152 |\n| Number of abortions, Median (Q1, Q3) | 2.00 (1.00, 3.00) | 2.00 (1.00, 3.00) | 0.202 |\n| Number of cesarean deliveries, Mean ± SD | 0.23 ± 0.42 | 0.39 ± 0.68 | 0.046 |\n| Concomitant ovarian cyst, n (%) | 0.102 | ||\n| No | 235 (91.8%) | 72 (85.7%) | |\n| Yes | 21 (8.2%) | 12 (14.3%) | |\n| Uterine position, n (%) | 0.005 | ||\n| Ante-position | 183 (71.5%) | 46 (54.8%) | |\n| Mid-position | 8 (3.1%) | 1 (1.2%) | |\n| Retro-position | 65 (25.4%) | 37 (44.0%) | |\n| Adenomyosis lesion location, n (%) | 0.437 | ||\n| Anterior wall | 52 (20.3%) | 14 (16.7%) | |\n| Posterior wall | 111 (43.4%) | 36 (42.9%) | |\n| Anterior and posterior walls | 55 (21.5%) | 16 (19.0%) | |\n| Lateral walls | 23 (9.0%) | 8 (9.5%) | |\n| Fundus | 15 (5.9%) | 10 (11.9%) | |\n| Lesion symmetry, n (%) | 0.615 | ||\n| No | 190 (74.2%) | 60 (71.4%) | |\n| Yes | 66 (25.8%) | 24 (28.6%) | |\n| Lower abdominal scar, n (%) | 0.216 | ||\n| No | 180 (70.3%) | 53 (63.1%) | |\n| Yes | 76 (29.7%) | 31 (36.9%) | |\n| Kishi classification, n (%) | <0.001 | ||\n| I | 140 (54.7%) | 11 (13.1%) | |\n| II | 33 (12.9%) | 26 (31.0%) | |\n| III | 32 (12.5%) | 5 (6.0%) | |\n| IV | 51 (19.9%) | 42 (50.0%) | |\n| T2WI signal intensity, n (%) | <0.001 | ||\n| Hypointense/Isointense | 187 (73.0%) | 17 (20.2%) | |\n| Hyperintense | 69 (27.0%) | 67 (79.8%) | |\n| Number of T2WI hyperintense foci, n (%) | <0.001 | ||\n| ≤5 | 134 (52.3%) | 18 (21.4%) | |\n| >5 | 122 (47.7%) | 66 (78.6%) | |\n| T2WI signal homogeneity, n (%) | <0.001 | ||\n| Homogeneous | 88 (34.4%) | 4 (4.8%) | |\n| Heterogeneous | 168 (65.6%) | 80 (95.2%) | |\n| T1WI signal intensity, n (%) | 0.122 | ||\n| Hypointense/Isointense | 239 (93.4%) | 74 (88.1%) | |\n| Hyperintense | 17 (6.6%) | 10 (11.9%) | |\n| T1WI signal homogeneity, n (%) | 0.947 | ||\n| Homogeneous | 68 (26.6%) | 22 (26.2%) | |\n| Heterogeneous | 188 (73.4%) | 62 (73.8%) | |\n| T1WI contrast enhancement, n (%) | <0.001 | ||\n| Mild/Moderate | 187 (73.0%) | 27 (32.1%) | |\n| Marked | 69 (27.0%) | 57 (67.9%) | |\n| T1WI enhancement homogeneity, n (%) | <0.001 | ||\n| Homogeneous | 92 (35.9%) | 14 (16.7%) | |\n| Heterogeneous | 164 (64.1%) | 70 (83.3%) |\nComparison of clinical and MRI characteristics between the low- and high-difficulty groups in the training cohort.\nP values were calculated using Pearson's χ2 test, Fisher's exact test, the Wilcoxon rank-sum test, or Welch's t test, as appropriate.\n3.4 Feature selection using lasso logistic regression\nThe 13 candidate variables with P < 0.10 in the univariable analysis were entered into a LASSO logistic regression model. Ten-fold cross-validation was used to determine the penalty parameter (λ). The P < 0.10 threshold was used as a pragmatic first-stage variable-reduction criterion rather than as an indicator of clinical relevance. To obtain a parsimonious model, λ1se = 0.034 was selected according to the 1-standard-error criterion (Figure 2B). At this λ value, LASSO retained 10 candidate predictors with nonzero coefficients: age, uterine volume, abdominal wall thickness, distance from the lesion center to the anterior abdominal skin, uterine position, Kishi classification, T2WI signal intensity, T2WI signal homogeneity, degree of contrast enhancement on T1WI, and T1WI enhancement homogeneity.\nFigure 2\n3.5 Multivariable logistic regression and identification of independent predictors\nThe 10 candidate variables selected by LASSO logistic regression were subsequently included in a multivariable logistic regression analysis. As shown in Table 5, six variables were independently associated with high ablation difficulty in US-guided HIFU: age <35 years (reference: ≥ 35 years; OR = 6.03, 95% CI: 2.57–14.82, P < 0.001), uterine volume (per 10 cm3 increase: OR = 0.95, 95% CI: 0.92–0.98, P = 0.003), abdominal wall thickness (per 1-mm increase: OR = 1.09, 95% CI: 1.03–1.15, P = 0.002), Kishi type IV (reference: type I; OR = 2.95, 95% CI: 1.15–7.82, P = 0.026), T2WI hyperintensity (reference: hypointensity/isointensity; OR = 5.87, 95% CI: 2.74–13.22, P < 0.001), and marked contrast enhancement on T1WI (reference: mild/moderate enhancement; OR = 2.59, 95% CI: 1.23–5.55, P = 0.013).\nTable 5\n| Characteristic | OR (95% CI) | P value |\n|---|---|---|\n| Age (years) | ||\n| ≥35 | Reference | — |\n| ˂35 | 6.03 (2.57–14.82) | <0.001 |\n| Uterine volume (cm3) | Per 10 cm3: 0.95 (0.92–0.98) | 0.003 |\n| Abdominal wall thickness (mm) | Per 1 mm: 1.09 (1.03–1.15) | 0.002 |\n| Distance from lesion center to abdominal wall (mm) | Per 10 mm: 1.06 (0.89–1.26) | 0.522 |\n| Uterine position | ||\n| Ante-position | Reference | — |\n| Mid-position | 0.73 (0.03–6.05) | 0.800 |\n| Retro-position | 1.40 (0.59–3.32) | 0.440 |\n| Kishi classification | ||\n| I | Reference | — |\n| II | 1.57 (0.53–4.65) | 0.410 |\n| III | 1.37 (0.30–5.52) | 0.667 |\n| IV | 2.95 (1.15–7.82) | 0.026 |\n| T2WI signal intensity | ||\n| Hypointense/Isointense | Reference | — |\n| Hyperintense | 5.87 (2.74–13.22) | <0.001 |\n| T2WI signal homogeneity | ||\n| Homogeneous | Reference | — |\n| Heterogeneous | 2.78 (0.92–10.44) | 0.091 |\n| T1WI contrast enhancement | ||\n| Mild/Moderate | Reference | — |\n| Marked | 2.59 (1.23–5.55) | 0.013 |\n| T1WI enhancement homogeneity | ||\n| Homogeneous | Reference | — |\n| Heterogeneous | 1.84 (0.78–4.56) | 0.172 |\nMultivariable logistic regression analysis of factors associated with high ablation difficulty in US-guided hIFU in the training cohort.\nFor continuous variables, ORs are reported per 10-cm3 increase in uterine volume, per 1-mm increase in abdominal wall thickness, and per 10-mm increase in the distance from the lesion center to the abdominal wall. OR, odds ratio; CI, confidence interval; T1WI, T1-weighted imaging; T2WI, T2-weighted imaging.\n3.6 Nomogram development, discrimination, and calibration\nThe six independent predictors identified by multivariable logistic regression—age, uterine volume, abdominal wall thickness, Kishi classification, T2WI signal intensity, and degree of contrast enhancement on T1WI—were incorporated into the nomogram (Figure 3). The model demonstrated good discrimination, with AUCs of 0.903 (95% CI: 0.867–0.939) in the training cohort and 0.923 (95% CI: 0.876–0.970) in the internal validation cohort (Figure 4). Sensitivity and specificity at the exploratory 70% predicted-probability threshold are provided in Supplementary Table S8. Bootstrap optimism correction yielded an optimism-corrected AUC of 0.887. Calibration curves showed overall agreement between predicted and observed probabilities in both cohorts (Figure 5), and numerical calibration measures are provided in Supplementary Table S8.\nFigure 3\nFigure 4\nFigure 5\n3.7 Clinical utility and sensitivity analyses\nDCA showed that the nomogram provided a generally higher net benefit than the treat-all and treat-none strategies across threshold probabilities of approximately 5%–80% in the training cohort (Figure 6A) and 5%–75% in the internal validation cohort (Figure 6B). Sensitivity analyses showed that several key predictors remained associated with continuous log(EEF) and NPVR <70%, whereas the treatment-intensity model showed weaker explanatory performance. The log(EEF) model yielded R2 values of 0.423 and 0.447, and the treatment-intensity model yielded R2 values of 0.168 and 0.069 in the training and internal validation cohorts, respectively. For NPVR <70%, the AUCs were 0.909 and 0.891, respectively. Detailed effect estimates, 95% confidence intervals, and P values are provided in Supplementary Tables S2, S3. At the 70% threshold, specificity exceeded 97% in both cohorts, whereas sensitivity was 40.5% in the training cohort and 46.7% in the internal validation cohort; detailed metrics are provided in Supplementary Table S8.\nFigure 6\n4 Discussion\nIn this study, we developed and internally validated a nomogram based on preprocedural MRI and clinical features to predict high ablation difficulty in patients with AM undergoing US-guided HIFU. The final model included six independent predictors: age, uterine volume, abdominal wall thickness, Kishi classification, T2WI signal intensity, and degree of contrast enhancement on T1WI. The nomogram showed good discrimination and calibration in both the training and internal validation cohorts. Unlike approaches that assess ablation outcome using NPVR alone, we constructed a composite ablation difficulty score incorporating EEF, treatment intensity, and NPVR. This outcome definition more comprehensively reflects ablation extent, energy efficiency, and sonication burden during treatment.\nAge <35 years was independently associated with high ablation difficulty in this cohort. However, the underlying explanation for this association remains uncertain. Younger patients may differ in hormonal status, lesion characteristics, fertility-preservation needs, and treatment-planning considerations (35, 36), but these mechanisms could not be directly evaluated in the present retrospective dataset. In particular, we did not record fertility intention, operator decision-making, or whether energy delivery was deliberately modified because of reproductive concerns. Therefore, the association between younger age and high ablation difficulty should be interpreted as a predictive statistical association rather than evidence of a confirmed biological or treatment-related mechanism.\nAn interesting and somewhat counterintuitive finding of this study was that larger uterine volume was associated with a lower risk of high ablation difficulty. This finding should not be interpreted as evidence that a larger uterus is biologically or clinically protective. We speculate that this association may be related to the combined effects of uterine size, lesion distribution, available safe ablation space, and the way treatment outcomes were measured. Previous studies have also shown that HIFU ablation outcomes in patients with AM are associated with adenomyotic lesion volume (37). In the present study, uterine volume was strongly correlated with adenomyotic lesion volume, indicating overlap between these two volume-related variables. In additional sensitivity analyses, when both uterine volume and adenomyotic lesion volume were included in the multivariable model, the association for uterine volume was attenuated and was no longer statistically significant, whereas model discrimination remained similar. In addition, NPVR is determined by both NPV and the pretreatment target volume. Residual nonablated regions, differences in target delineation, and errors in volume measurement may therefore affect the stability of NPVR estimates (32). Therefore, this inverse association may partly reflect collinearity between volume-related variables, the denominator effect of NPVR calculation, adjustment for Kishi classification, and residual confounding inherent in the retrospective design. The inverse association between uterine volume and high ablation difficulty observed in this study may reflect the combined influence of uterine size, lesion distribution, safety margins, and NPVR calculation, consistent with previous findings (22, 38). Accordingly, this result should be regarded as a statistical association requiring further validation rather than a direct causal or protective effect.\nAbdominal wall thickness was another independent predictor, with greater thickness associated with high ablation difficulty. US-guided HIFU requires ultrasound energy to pass through prefocal tissues, including the abdominal wall, before being focused within the target region. Therefore, the characteristics of the acoustic pathway may affect the efficiency of energy deposition within the target. Previous studies have reported associations of abdominal wall thickness and subcutaneous fat thickness with ablation-related parameters, including NPVR and EEF (39, 40). From a physical perspective, ultrasound waves may undergo reflection, scattering, and absorption as they pass through interfaces between the skin, subcutaneous fat, fascia, and muscle, thereby reducing the effective acoustic energy delivered to the target. Adipose tissue may also attenuate and defocus the HIFU acoustic field, reducing focal intensity and impairing heat deposition (41). A thicker abdominal wall may therefore increase the propagation distance and energy loss within prefocal tissues, resulting in greater energy requirements for ablation of a given lesion volume. This may be reflected by higher treatment intensity or EEF and contribute to greater overall ablation difficulty.\nThe Kishi classification is an MRI-based system that categorizes AM into intrinsic, extrinsic, intramural, and indeterminate types according to the location and spatial distribution of lesions within the myometrium (30). Type IV represents indeterminate lesions whose morphology and distribution do not conform to the other three typical patterns and may therefore reflect greater spatial heterogeneity. In the present study, Kishi type IV was independently associated with high ablation difficulty in US-guided HIFU and corresponded to a relatively high point score in the nomogram. Lesion distribution may affect target delineation, acoustic pathway planning, energy deposition, and maintenance of safe margins from adjacent structures. The atypical distribution of Kishi type IV lesions may therefore increase the complexity of target definition, acoustic pathway establishment, and safety-margin control. When adjacent structures such as the bowel restrict the acoustic pathway, adjunctive displacement maneuvers may also be required (42). Previous studies have reported differences in US-guided HIFU outcomes among patients with different MRI classifications (24), supporting the association between Kishi type IV and high ablation difficulty.\nMRI signal characteristics were also important components of the prediction model. Both T2WI signal intensity and the degree of contrast enhancement on T1WI were independently associated with HIFU ablation difficulty. Hyperintensity on T2WI may reflect increased water content, heterogeneous tissue composition, local hemorrhage, or cystic changes within adenomyotic lesions (43), which may influence ultrasound energy deposition. Marked contrast enhancement on T1WI generally indicates relatively abundant vascularity. Greater local perfusion may increase heat dissipation and reduce the efficiency of thermal deposition, thereby complicating the energy delivery required to achieve adequate coagulative necrosis (44). Together, these two MRI features may reflect differences in lesion response to HIFU energy from the perspectives of tissue composition and blood perfusion.\nTo provide a more comprehensive assessment of both the effectiveness and efficiency of US-guided HIFU ablation for AM, we developed a composite ablation difficulty score incorporating NPVR, EEF, and treatment intensity. Because the EEF and treatment-intensity thresholds were derived from the training cohort, they should be interpreted as cohort-specific operational cutoffs rather than generalizable clinical thresholds. Such data-derived thresholds may influence outcome prevalence and apparent model performance and may limit their transportability across populations. Although NPVR reflects the immediate extent of ablation, it does not account for the time and energy required to achieve that result (45, 46). The inclusion of EEF and treatment intensity provides additional information on energy efficiency and time utilization, respectively, thereby addressing the limitations of assessment systems based primarily on ablation extent (47, 48). The equal weighting and >3 cutoff were used as an exploratory framework and should not be considered established clinical standards. The sensitivity analyses using continuous EEF, continuous treatment intensity, and NPVR <70% as alternative endpoints suggested that the main findings were not solely dependent on the original categorical score. Nevertheless, external validation and prospective refinement are required before these thresholds can be used as fixed clinical decision cutoffs across institutions. Accordingly, high ablation difficulty in the present study refers to the need for greater energy input per unit volume or a higher sonication burden to achieve a comparable effective ablation volume. Thus, “ablation difficulty” should be interpreted as an operational measure of overall treatment burden and technical effort rather than a pure measure of intrinsic procedural complexity. Previous studies have mainly used preprocedural MRI characteristics or imaging classifications to predict outcomes such as NPVR, ablation rate, or long-term clinical response, and differences in treatment parameters and outcomes have been reported among MRI subtypes (26, 49). In contrast, the present study used a composite measure of ablation difficulty as the prediction outcome and incorporated key imaging features, including Kishi classification and T2WI signal intensity. Kishi type IV and T2WI hyperintensity were independently associated with high ablation difficulty, suggesting that lesion distribution and tissue composition may affect not only ablation outcomes but also target planning and the efficiency of energy delivery. The nomogram may therefore assist in the preprocedural identification of patients who are likely to require greater energy input or longer treatment duration and may provide useful information for risk stratification, estimation of treatment requirements, and patient counseling. For practical clinical interpretation, patients with a predicted probability of high ablation difficulty >70% may be considered a high-risk subgroup requiring more detailed preprocedural counseling, allocation of sufficient procedure time, experienced operator involvement, careful acoustic pathway planning, and closer intraoperative monitoring. The 70% threshold was selected as a pragmatic and clinically interpretable reference to identify patients with a relatively high predicted risk and should be regarded as exploratory rather than as a validated clinical cutoff. Further prospective external validation is required before this threshold can be adopted as a standardized clinical decision rule.\nSeveral limitations should be acknowledged. First, the single-center retrospective design may have introduced selection bias. Accumulated operator experience over the long study period may still have influenced treatment-related parameters. Second, the model was evaluated only in a randomly split internal validation cohort and was not externally validated in an independent population. Its generalizability across institutions and clinical settings therefore requires confirmation in prospective multicenter studies. The two-stage variable-selection strategy may have excluded clinically relevant predictors and may affect model stability. Additionally, categorizing age at 35 years may have resulted in information loss and may not fully capture the continuous association between age and ablation difficulty. Furthermore, the linearity assumption for continuous predictors was not formally assessed, and potential nonlinear relationships may have affected the model estimates. The applicability of this scoring system requires further validation in large, independent multicenter populations. These limitations may restrict the direct application of the model across different clinical settings and patient populations.\nIn conclusion, we developed and internally validated a nomogram based on preprocedural MRI and clinical features to predict high ablation difficulty in patients with AM undergoing US-guided HIFU. The model showed good discrimination and calibration and demonstrated potential clinical utility for preprocedural risk assessment and individualized treatment planning.\nStatements\nData availability statement\nThe original contributions presented in the study are included in the article/Supplementary Material, further inquiries can be directed to the corresponding author.\nEthics statement\nThe studies involving humans were approved by The Ethics Committee of the Affiliated Hospital of North Sichuan Medical College. The studies were conducted in accordance with the local legislation and institutional requirements. Written informed consent for participation was not required from the participants or the participants’ legal guardians/next of kin in accordance with the national legislation and institutional requirements.\nAuthor contributions\nQG: Data curation, Investigation, Methodology, Writing – original draft. PW: Methodology, Software, Writing – original draft, Formal Analysis. FZ: Data curation, Writing – original draft. ZR: Data curation, Writing – original draft. WL: Data curation, Writing – original draft. HZ: Funding acquisition, Project administration, Supervision, Visualization, Writing – review & editing.\nFunding\nThe author(s) declared that financial support was received for this work and/or its publication. This study was supported by the Sichuan Joint Fund of Science and Education, Sichuan Provincial Department of Science and Technology (Grant No. 2025NSFSC2148).\nConflict of interest\nThe author(s) declared that this work was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.\nGenerative AI statement\nThe author(s) declared that generative AI was not used in the creation of this manuscript.\nAny alternative text (alt text) provided alongside figures in this article has been generated by Frontiers with the support of artificial intelligence and reasonable efforts have been made to ensure accuracy, including review by the authors wherever possible. If you identify any issues, please contact us.\nPublisher’s note\nAll claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article, or claim that may be made by its manufacturer, is not guaranteed or endorsed by the publisher.\nSupplementary material\nThe Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fmed.2026.1954919/full#supplementary-material\nReferences\n1.\nChapronCVannucciniSSantulliPAbrãoMSCarmonaFFraserISet al. Diagnosing adenomyosis: an integrated clinical and imaging approach. Hum Reprod Update. (2020) 26(3):392–411. 10.1093/humupd/dmz049\n2.\nBulunSEYildizSAdliMWeiJ-J. Adenomyosis pathogenesis: insights from next-generation sequencing. Hum Reprod Update. (2021) 27(6):1086–1097. 10.1093/humupd/dmab017\n3.\nLoringMChenTYIsaacsonKB. A systematic review of adenomyosis: it is time to reassess what we thought we knew about the disease. J Minim Invasive Gynecol. (2021) 28(3):644–655. 10.1016/j.jmig.2020.10.012\n4.\nMoawad G, Fruscalzo A, Youssef Y, Kheil M, Tawil T, Nehme J, et al. Adenomyosis. An updated review on diagnosis and classification. J Clin Med. (2023) 12(14):4828. doi: 10.3390/jcm12144828\n5.\nBourdonMSantulliPMarcellinLMaignienCMaitrot-ManteletLBordonneCet al. Adenomyosis: an update regarding its diagnosis and clinical features. J Gynecol Obstet Hum Reprod. (2021) 50(10):102228. 10.1016/j.jogoh.2021.102228\n6.\nNelsenLMLenderkingWRPokrzywinskiRBalantacZBlackLPokrasSet al. Experience of symptoms and disease impact in patients with adenomyosis. Patient. (2018) 11(3):319–328. 10.1007/s40271-017-0284-2\n7.\nDasonESMaximMSandersAPapillon-SmithJNgDChanCet al. Guideline no. 437: diagnosis and management of adenomyosis. J Obstet Gynaecol Can. (2023) 45(6):417–429.e1. 10.1016/j.jogc.2023.04.008\n8.\nCapezzuoliTToscanoFCeccaroniMRoviglioneGStepniewskaAFambriniMet al. Conservative surgical treatment for adenomyosis: new options for looking beyond uterus removal. Best Pract Res Clin Obstet Gynaecol. (2024) 95:102507. 10.1016/j.bpobgyn.2024.102507\n9.\nBischiniotisSMikosTGrimbizisGF. Surgical treatment of adenomyosis. Curr Obstet Gynecol Rep. (2024) 13(2):80–87. 10.1007/s13669-024-00383-0\n10.\nEtruscoABarraFChianteraVFerreroSBoglioloSEvangelistiGet al. Current medical therapy for adenomyosis: from bench to bedside. Drugs. (2023) 83(17):1595–1611. 10.1007/s40265-023-01957-7\n11.\nSauerbrun-CutlerMTAlveroR. Short- and long-term impact of gonadotropin-releasing hormone analogue treatment on bone loss and fracture. Fertil Steril. (2019) 112(5):799–803. 10.1016/j.fertnstert.2019.09.037\n12.\nLiuLTianHLinDZhaoLWangHHaoY. Risk of recurrence and reintervention after uterine-sparing interventions for symptomatic adenomyosis: a systematic review and meta-analysis. Obstet Gynecol. (2023) 141(4):711–723. 10.1097/AOG.0000000000005080\n13.\nYounesGTulandiT. Conservative surgery for adenomyosis and results: a systematic review. J Minim Invasive Gynecol. (2018) 25(2):265–276. 10.1016/j.jmig.2017.07.014\n14.\nBahutairSNAlhubaishiLY. High-intensity focused ultrasound in adenomyosis treatment: insights on safety, efficacy, and reproductive prospects. Womens Health (Lond). (2024) 20:17455057241295593. 10.1177/17455057241295593\n15.\nZhangLRaoFSetzenR. High intensity focused ultrasound for the treatment of adenomyosis: selection criteria, efficacy, safety and fertility. Acta Obstet Gynecol Scand. (2017) 96(6):707–714. 10.1111/aogs.13159\n16.\nDe MaioAAlfieriGMattoneMGhanouniPNapoliA. High-intensity focused ultrasound surgery for tumor ablation: a review of current applications. Radiology. (2024) 6(1):e230074. 10.1148/rycan.230074\n17.\nBachuVSKeddaJSukIGreenJJTylerB. High-intensity focused ultrasound: a review of mechanisms and clinical applications. Ann Biomed Eng. (2021) 49(9):1975–1991. 10.1007/s10439-021-02833-9\n18.\nMoonenCTWKilroyJPKlibanovAL. Focused ultrasound: noninvasive image-guided therapy. Invest Radiol. (2025) 60(3):205–219. 10.1097/RLI.0000000000001116\n19.\nChenYLinSXieXYiJLiuXGuoS-W. Systematic review and meta-analysis of reproductive outcomes after high-intensity focused ultrasound (HIFU) treatment of adenomyosis. Best Pract Res Clin Obstet Gynaecol. (2024) 92:102433. 10.1016/j.bpobgyn.2023.102433\n20.\nMarquesALSAndresMPKhoRMAbrãoMS. Is high-intensity focused ultrasound effective for the treatment of adenomyosis? A systematic review and meta-analysis. J Minim Invasive Gynecol. (2020) 27(2):332–343. 10.1016/j.jmig.2019.07.029\n21.\nZhouMChenJ-YTangL-DChenW-ZWangZ-B. Ultrasound-guided high-intensity focused ultrasound ablation for adenomyosis: the clinical experience of a single center. Fertil Steril. (2011) 95(3):900–5. 10.1016/j.fertnstert.2010.10.020\n22.\nGongCYangBShiYLiuZWanLZhangHet al. Factors influencing the ablative efficiency of high intensity focused ultrasound (HIFU) treatment for adenomyosis: a retrospective study. Int J Hyperthermia. (2016) 32(5):496–503. 10.3109/02656736.2016.1149232\n23.\nKeserciBDucNM. Magnetic resonance imaging features influencing high-intensity focused ultrasound ablation of adenomyosis with a nonperfused volume ratio of ≥90% as a measure of clinical treatment success: retrospective multivariate analysis. Int J Hyperthermia. (2018) 35(1):626–636. 10.1080/02656736.2018.1516301\n24.\nTangYHuW-WangHWuJWenM-SuBet al. Magnetic resonance imaging-based classification systems for informing better outcomes of adenomyosis after ultrasound-guided high-intensity focused ultrasound ablating surgery. J Magn Reson Imaging. (2024) 59(5):1787–1797. 10.1002/jmri.28943\n25.\nYuJ-WYangM-JJiangLSuX-YChenJ-Y. Factors influencing USgHIFU ablation for adenomyosis with NPVR ≥ 50%. Int J Hyperthermia. (2023) 40(1):2211753. 10.1080/02656736.2023.2211753\n26.\nLiZZhangJSongYYinXChenATangNet al. Utilization of radiomics to predict long-term outcome of magnetic resonance-guided focused ultrasound ablation therapy in adenomyosis. Eur Radiol. (2021) 31(1):392–402. 10.1007/s00330-020-07076-1\n27.\nYingJJingXGaoFChengJFuLYangH. Prediction of ablation rate for high-intensity focused ultrasound therapy of adenomyosis in MR images based on multi-model fusion. J Imaging Inform Med. (2024) 37(4):1579–1590. 10.1007/s10278-024-01063-4\n28.\nLiuZLiuZWanXWangYHuangX. Prediction of clinical outcome for high-intensity focused ultrasound ablation of adenomyosis based on non-enhanced MRI radiomics. Int J Hyperthermia. (2025) 42(1):2468766. 10.1080/02656736.2025.2468766\n29.\nSunMDengXXingHZhangRFuBAiTet al. A dual-sequence MRI-based radiomics model for predicting high-intensity focused ultrasound ablation efficacy in adenomyosis treatment. Int J Womens Health. (2025) 17:1321–1332. 10.2147/IJWH.S512216\n30.\nKishiYSuginamiHKuramoriRYabutaMSuginamiRTaniguchiF. Four subtypes of adenomyosis assessed by magnetic resonance imaging and their specification. Am J Obstet Gynecol. (2012) 207(2):114.e1–7. 10.1016/j.ajog.2012.06.027\n31.\nGongCSetzenRLiuZLiuYXieBAiliAet al. High intensity focused ultrasound treatment of adenomyosis: the relationship between the features of magnetic resonance imaging on T2 weighted images and the therapeutic efficacy. Eur J Radiol. (2017) 89:117–122. 10.1016/j.ejrad.2017.02.001\n32.\nBaeJSLeeJYChungHHLeeMJeonMJKimHet al. Optimized treatment parameter by computer simulation for high-intensity focused ultrasound treatment of uterine adenomyosis: short-term and long-term results. PLoS One. (2024) 19(3):e0301193. 10.1371/journal.pone.0301193\n33.\nXuFLinZWangYGongCHeMGuoQet al. Comparison of high-intensity focused ultrasound for the treatment of internal and external adenomyosis based on magnetic resonance imaging classification. Int J Hyperthermia. (2023) 40(1):2211268. 10.1080/02656736.2023.2211268\n34.\nZhangYWangQWangYMaRHeMZhangL. A novel scoring system based on magnetic resonance imaging for the prediction of the difficulty of ultrasound-guided high-intensity focused ultrasound ablation for uterine fibroids. Int J Hyperthermia. (2024) 41(1):2386098. 10.1080/02656736.2024.2386098\n35.\nZhaiJVannucciniSPetragliaFGiudiceLC. Adenomyosis: mechanisms and pathogenesis. Semin Reprod Med. (2020) 38(2-03):129–143. 10.1055/s-0040-1716687\n36.\nBulunSEYildizSAdliMChakravartiDParkerJBMiladMet al. Endometriosis and adenomyosis: shared pathophysiology. Fertil Steril. (2023) 119(5):746–750. 10.1016/j.fertnstert.2023.03.006\n37.\nZhaoYLuoSLiuYHeYLiuXGuohuaHet al. High intensity focused ultrasound treatment for adenomyosis: comparison of efficacy based on MRI features. Int J Hyperthermia. (2023) 40(1):2197574. 10.1080/02656736.2023.2197574\n38.\nLiuZLiuZWangYWanXHuangX. Machine learning-based predictive analysis of energy efficiency factors necessary for the HIFU treatment of adenomyosis. Front Physiol. (2025) 16:1602866. 10.3389/fphys.2025.1602866\n39.\nKeserciBDucNM. Magnetic resonance imaging parameters in predicting the treatment outcome of high-intensity focused ultrasound ablation of uterine fibroids with an immediate nonperfused volume ratio of at least 90%. Acad Radiol. (2018) 25(10):1257–1269. 10.1016/j.acra.2018.01.022\n40.\nSuomiVKomarGSainioTJoronenKPerheentupaABlanco SequeirosR. Comprehensive feature selection for classifying the treatment outcome of high-intensity ultrasound therapy in uterine fibroids. Sci Rep. (2019) 9(1):10907. 10.1038/s41598-019-47484-y\n41.\nRitchieRCollinJCoussiosCLeslieT. Attenuation and de-focusing during high-intensity focused ultrasound therapy through peri-nephric fat. Ultrasound Med Biol. (2013) 39(10):1785–93. 10.1016/j.ultrasmedbio.2013.04.010\n42.\nLaiMChenYLiHLiYWuSLiZet al. A modified bowel displacement technique for magnetic resonance imaging-guided focused ultrasound surgery in the treatment of uterine fibroids and adenomyosis. J Comput Assist Tomogr. (2022) 46(3):379–382. 10.1097/RCT.0000000000001301\n43.\nAgostinhoLCruzROsórioFAlvesJSetúbalAGuerraA. MRI for adenomyosis: a pictorial review. Insights Imaging. (2017) 8(6):549–556. 10.1007/s13244-017-0576-z\n44.\nKeserciBDucNM. The role of T1 perfusion-based classification in predicting the outcome of magnetic resonance-guided high-intensity focused ultrasound treatment of adenomyosis. Int J Hyperthermia. (2018) 34(3):306–314. 10.1080/02656736.2017.1326634\n45.\nTempanyCMCStewartEAMcDannoldNQuadeBJJoleszFAHynynenK. MR imaging-guided focused ultrasound surgery of uterine leiomyomas: a feasibility study. Radiology. (2003) 226(3):897–905. 10.1148/radiol.2271020395\n46.\nStewartEAGostoutBRabinoviciJKimHSReganLTempanyCMC. Sustained relief of leiomyoma symptoms by using focused ultrasound surgery. Obstet Gynecol. (2007) 110(2 Pt 1):279–87. 10.1097/01.AOG.0000275283.39475.f6\n47.\nLi F, Wang Z, Du Y, Ma P, Bai J, Wu F, et al. [Study on therapeutic dosimetry of HIFU ablation tissue]. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. (2006) 23(4):839–843. PubMed (PMID: 17002121).\n48.\nShuiLMaoSWuQHuangGWangJZhangRet al. High-intensity focused ultrasound (HIFU) for adenomyosis: two-year follow-up results. Ultrason Sonochem. (2015) 27:677–681. 10.1016/j.ultsonch.2015.05.024\n49.\nLiu R, Hao H, Yin Y, Chen L, Liu Y. Effect of high-intensity focused ultrasound on different types of adenomyosis based on magnetic resonance imaging classification. J Ultrasound Med. (2024) 43(10):1947–1955. doi: 10.1002/jum.16529\nSummary\nKeywords\nablation difficulty, adenomyosis, nomogram, prediction model, ultrasound-guided high-intensity focused ultrasound\nCitation\nGuo Q, Wu P, Zhang F, Ren Z, Li W and Zhou H (2026) Development and internal validation of a nomogram based on MRI and clinical features for predicting high ablation difficulty in ultrasound-guided HIFU for adenomyosis. Front. Med. 13:1954919. doi: 10.3389/fmed.2026.1954919\nReceived\n31 July 2026\nRevised\n07 October 2026\nAccepted\n03 November 2026\nPublished\n18 November 2026\nVolume\n13 - 2026\nEdited by\nQuanfu Zhang, Baoan Women’s and Children’s Hospital, China\nReviewed by\nNitish Kumar Singh, Banaras Hindu University, India\nMingtao Yang, Nanchong Central Hospital, China\nUpdates\nCopyright\n© 2026 Guo, Wu, Zhang, Ren, Li and Zhou.\nThis is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.\n*Correspondence: Honggui Zhou hongguizhou@163.com\n† These authors have contributed equally to this work and share first authorship\nDisclaimer\nAll claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.","source_license":"CC0","license_restricted":false}